Ge Security 60–983 Atp1000 Alphanumeric Touchpad User Manual

tutornew
4 min readMay 26, 2021

Download here

  • Appliance manuals and free pdf instructions. Find the user manual you need for your home appliance products and more at ManualsOnline.
  • The 60–983 is an ATP1000 Alphanumeric Touchpad from Interlogix that can promote high operation while allowing for on-site installer programming.

Atp1000 touchpad/display installation instructions, Product summary, Installation

Interlogix 60–983 ATP1000 Alphanumeric Touchpad: Large 2X16 Liquid Crystal Display w/Adjustable Contrast and Brightness. Swing-Down, Removable Door. Police, Fire and Auxiliary Panic Buttons. Allows for On-Site Installer Programming. Control Concord panels with the ATP-1000 Alphanumeric programmable touchpad.

Advertising

ATP1000 Touchpad/Display Installation

Instructions

Product summary

The ATP1000 lets you control all programming and operation
of compatible security systems (see the “Specifications”
section).

The large 2-line, 16-character display provides easy to read
messages to indicate the current status of the system. The
touchpad includes police, fire, and auxiliary panic buttons that
can be activated anytime. A built-in speaker provides alarm,
status, and button-press sounds. A swing-down door reveals a
label with basic system operating commands. The door can be
removed by simply opening it past its stop point. The door can
also be reattached later if desired.

Tools and equipment needed

4-conductor, 22- or 18-gauge wire

Screwdriver

#6 screws and anchors (included)

Panhead screws for gang box installation

Saw or utility knife for cutting wallboard

Installation

Installation guidelines

Mount the touchpad in an environmentally controlled area
(32°F to 120°F/0°C to 49°C).

When mounting the touchpad, allow at least 3 inches
below it for the swing-down cover.

Do not exceed the maximum available power. See the
panel installation instructions for maximum available
power.

Table 1

describes the power used by the touchpad.

Table 2

describes the maximum wire lengths allowed

between the touchpad and the panel.

Table 1. Touchpad power usage
Current (mA)

Conditions

110

Maximum alarm current with the buzzer sounding

and the touchpad illuminated from a button press

60

Typical operation

12

Power saving mode (no panel AC power)

Table 2. Maximum touchpad wire lengths
Wire Gauge (Unshielded

or Shielded)

Max. Touchpad Wire Length

Between Touchpad and Panel

18

750 feet

22

300 feet

Installing the Mounting Plate

1. Separate the mounting plate from the touchpad by first

loosening the screw, then lift the touchpad away from the
mounting plate (see

Figure 1

).

Figure 1. Separating touchpad from mounting plate

Loosen screw,

then lift touchpad.

P/N 466–2100 • REV I • January 2011

1

Advertising

Table of contents

  • Product summary
  • Tools and equipment needed
  • Installation
  • Installation guidelines
  • Installing the Mounting Plate
  • Connecting the touchpad for system programming only
  • Adjusting display brightness and contrast
  • Changing the touchpad unit number(Concord panels with software version 1.0–1.6 only)

Popular Brands

Popular manuals

Advertising

2. For wall mounting, place the mounting plate on the wall

and mark the mounting holes (see

). Be sure to

leave a 3-inch clearance below for the touchpad door to

open.

Figure 2. Mounting hole locations

Mounting Holes

Mounting Holes

3. Insert anchors into the wall at the marked locations where

studs are not present.

4. Align the mounting plate holes with the wall or gang box

screw holes and secure the back plate using the screws

provided.

Note: Do not over tighten screws or the mounting plate

may bind and prevent the touchpad from mounting

Ge Security 60–983 Atp1000 Alphanumeric Touchpad User Manual Online

properly.

5. For wall-mount installations, cut a hole in the wall in the

wire access area of the mounting plate to pull the wiring

cable through.

Wiring the Touchpad to the Panel

1. Remove panel AC and backup battery power.

2. Run a 4-conductor, 18- to 22-gauge wire from the panel to

the touchpad location (see

3. Connect the touchpad +12V, BUS A, BUS B, and GND

terminals to the matching panel terminals (see Figure 3 for

touchpad terminal identification)

Figure 3. Touchpad wiring connections

GND

BUS B
BUS A

+12V

Attaching the Touchpad to the Mounting Plate

Align the tabs at the top of the mounting plate with the slots on

the touchpad and swing the touchpad bottom toward the

mounting plate. Gently tighten the screw into the bottom of the

touchpad.

Power up and Bus communication

After making all wiring connections from the touchpad to the

panel, you are ready to power up the panel and verify correct

communication between the touchpad and the panel. Upon

power up, the panel scans the bus for connected devices,

assigns a unit number to each bus device, and automatically

learns the device ID number of each bus device.

Ge Security 60–983 Atp1000 Alphanumeric Touchpad User Manual Software

1. Verify that all wiring between the panel and touchpad is

correct.

2. Connect the panel battery and restore AC power.

Alphanumeric touchpads briefly show SCANNING BUS

Ge Security 60–983 Atp1000 Alphanumeric Touchpad User Manual Template

DEVICES, then display date and time.

Note: Steps 3 through 9 are optional.

3. At the touchpad, enter program mode by pressing 8 +

installer/dealer code (default = 4321) + 0 + 0. The

touchpad should display SYSTEM PROGRAMMING.

4. Press É and the display shows SECURITY.

5. Press A or B until the display shows ACCESSORY

MODULES, then press É. The display should read BUS

DEVICES.

6. Press É. The display shows the lowest device address

and its ID. The following example shows what a device

address display may look like:

UNIT — ID

0–02110185*

*The 8-digit SuperBus ID number is also located on a label

on back of the touchpad.

7. Press A or B to cycle through all bus device addresses

until the touchpad appears.

8. After verifying the touchpad device ID, press Ç repeatedly

until the display shows SYSTEM PROGRAMMING.

9. Press A or B until the display shows EXIT

PROGRAMMING READY, then press É. The touchpad

should show the date and time display.

Programming

To program options for the newly installed touchpad (such as

key beeps) see the specific panel installation instructions.

2

ATP1000 Touchpad/Display Installation Instructions

Advertising

Popular Brands